Bayliner 265 Specifications Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
265 Owner’s Manual Supplement Chapter 6: Plumbing
41
Freshwater System Winterization
1. Turn On the freshwater pump switch.
2. Open all of the faucets and showers and let the freshwater system drain completely.
3. Turn Off the freshwater pump switch.
All remaining water must be removed from the water lines. There are two ways to remove the remaining water from
the lines:
Compressed Air
Gravity Draining
Compressed Air
You must have an air compressor with an air hose and
an air nozzle.
1. Remove the water line from the outlet side of the
freshwater pump (opposite side from filter).
2. Open the faucet that is furthest away from the fresh-
water pump.
3. Place the air nozzle against the end of the just
removed water line and blow air through
the system.
4. When water stops coming out of the Open
faucet, stop the air and Close the faucet.
5. One at a time, repeat this process on all faucets and
showers.
Gravity Draining
1. Open all faucets and showers.
2. Remove the drain plug from the tee fitting on the
freshwater tank.
3. When the water has stopped draining from the
freshwater tank, replace the drain plug.
WATER SYSTEM DAMAGE HAZARD!
NEVER blow compressed air through the water system when all of the faucets are Closed.
CAUTION
!
TYPICAL VIEW
NOTE: LOCATION OF TEE FITTING
& DRAIN PLUG MAY VARY
FRESHWATER TANK
FILTER
FRESHWATER
OUTLET SIDE
WATER LINE
INLET SIDE
WATER LINE
DRAIN PLUG
TEE FITTING
PUMP
Page view 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 83 84

Comments to this Manuals

No comments